Polyfin 4018 v

Art.No. F0842

Product

Synthetic roofing sheet with glass-fibre reinforcement, FPO, bitumen compatible

Top side / Bottom side

Top side

grey

Bottom side

nonwoven fabric

Intended use

  • Roof waterproofing sheet loose laid with ballast and below other utility layers
  • Exposed roof waterproofing sheet mechanically fastened
  • Roof waterproofing sheet fully bonded
  • Roof waterproofing sheet bonded in strips

Application

Hot air welding method

Standard

EN 13956, EN 13967

Packaging

23 rolls of 15 m x 1.5m = 517.5 m² per pallet

Characteristics Testing method Unit Result
Visible defects EN 1850-2 - None
Length EN 1848-2 m 15,0
Width EN 1848-2 m 1,5
Straightness EN 1848-2 mm ≤ 30
Flatness EN 1848-2 mm ≤ 10
Thickness EN 1849-2 mm 1,8
Mass per unit area EN 1849-2 kg/m² ?
Watertightness (Verf. B) EN 1928 kPa ≥ 500
External fire exposure EN 13501-5 Broof(t1) [1]
Reaction to fire test EN 13501-1 Class E
Hail resistance (rigid substrate) EN 13583 m/s ≥ 25
Hail resistance (flexible substrate) EN 13583 m/s ≥ 35
Peel resistance of joints EN 12316-2 N/50 mm ≥ 400
Shear resistance of joints long./trans. EN 12317-2 N/50 mm ≥ 450
Chemical properties EN 1847 passed
Water vapour transmission EN 1931 μ 90.000
Tensile force long./trans. EN 12311-2 N/50 mm ≥ 900
Elongation at single-end breaking force EN 12311-2 % ≥ 50
Resistance to impact (rigid substrate) EN 12691 mm ≥ 500
Resistance to impact (flexible substrate) EN 12691 mm ≥ 1500
Resistance to static loading EN 12730 kg ≥ 20
Resistance to tearing (nail shank) long./trans. EN 12310-2 N ≥ 150
Resistance to tearing (nail shank) long./trans. EN 12310-1 ≥ 300
Dimensional stability EN 1107-2 % ≤ |0,3|
Foldability EN 495-5 °C ≤ -40
Root resistance EN 13948/FLL-Prüfverfahren passed
UV-exposure EN 1297 > 5000 h passed (Class 0)
Exposure to bitumen EN 1548 passed

[1] according to certified system